Model | ZYH-40J | ZYH-60 | ZYH-80 |
Flow rate | 30-40 L/min | 50-60 L/min | 70-80 L/min |
Rated Voltage | AC220V | AC220V/110V | AC220V/110V |
Rated Power | 120W | 550W | 750W |
Pressure | 0.16-0.18MPa 1.6-1.8bar 23-26psi |
0.18-0.20MPa 1.8-2.0bar 26-29psi |
|
Sucking | 2-4m | 3-5m | |
Head | 4-8m | 10-20m | |
Inlet/Outlet Thread | In BSP3/4" Out BSP3/4 |
In BSP1" Out BSP1" |
Common Troubleshooting | ||
Fault Apperance | Main Reason | Fault Resolution |
Motor does not turn | 1.The power cable is not plugged in | 1.Check the electric cable |
2.The motor has jammed | 2.Replace the motor | |
3.Capacitor failure | 3.Replace capacitors | |
Motor turns, but no oil output | 1.Suction side not submerged in oil | 1.Check the oil suction hose/pipe |
2.Vanes worn or gear damaged | 2.Replace vanes or gear | |
Abnormal metering or no meter output | Computation swing tray has broken | Replace the computation swing tray |
Little oil-output | Plugged strainer | Clean the strainer |